Login
English
(EUR)
CO2 sensor 1Wire-UNI
Temperature, humidity and CO2 interior detector with 3M 1Wire-Uni connection. Modern design for inconspicuous installations in offices, flats or public buildings. Suitable for all HWG units supporting 1Wire-Uni protocol. The presence of CO2 is increasingly ...More information
Producer
HW group
Part No.
600746
Code
00071046
Warranty
24 Month
Order
Your price exc. VAT
248.35 EUR
exc. VAT
VAT
21%
Your price inc. VAT
300.50 EUR
inc. VAT
Ask for a better price
Products classification
Product question
Product question
Do you need help?
We will help you with product selection or technical problems.
(+420) 246 035 451
Information and orders
Jan Mencl
Product manager
(+420) +420 778 885 932
mencl@vanco.cz
GPSR
Last visited

Description
Temperature, humidity and CO2 interior detector with 3M 1Wire-Uni connection. Modern design for inconspicuous installations in offices, flats or public buildings. Suitable for all HWG units supporting 1Wire-Uni.
The presence of CO2 is an increasingly discussed problem in premises with a high concentration of persons. It is proven that"exhaled" air with a high CO2 content has a very negative impact on attention, fatigue and higher doses and on the health of the population. Installation of CO2 monitoring becomes common in educational premises and in the private sector.
where to use:
- Schools, kindergartens, places with higher concentration of persons
- offices, meeting rooms, corridors
- apartment buildings, hotels, guest houses
- offices, waiting rooms, sports halls
measurement accuracy:- temperature
- Measurement range--30-+70 ° C
- measurement accuracy-0.8 ° C
- resolution-0.1 °
- moisture
- Measurement range-0-100 # i6per # rh
- Measurement accuracy-5# i6per# rh at 25 ° C
- resolution-0.1 # i6per # rh
- CO2
- Measurement range-300-40000 ppm
- resolution-1 ppm in range 0 ppm-2008 ppm, 6ppm in 2008 ppm-11110 ppm and 32ppm in the range of 11110 ppm-60000 ppm
- Measurement accuracy-50ppm + 3 #i6per #
- temperature stability ± 2.5 ppm/° C (in the range of 0-50 ° C)
Technical properties:- Maximum length 1-Wire bus-20m
- Maximum number of sensors per 1-Wire UNI port-1 (in case of multiple need to use 1-Wire Hub Power)
- sensor dimensions-60x60x20 mm
- degree of protection-IP30
- Communication interface-bus 1-Wire via RJ-11 connector.
- Combined sensor 3 values -on the bus looks like 3 independent sensors
- Power supply 5V out of 1-Wire port